How to set maxcc in jcl
WebMani, I use a JCL as below : ... DELETE - PURGE IF MAXCC < 8 THEN SET MAXCC = 0 HTH Varun Computer Sciences Corporation India Private Limited Registered Office: Electronics Complex, Software Technology Park, Indore, Madhya Pradesh, India Registered in India No: 10-11210 ----- This is a PRIVATE message. ... WebUse the SET command to change or reset a previously defined condition You can end all processing by setting MAXCC or LASTCC to 16. The syntax of the SET command is: …
How to set maxcc in jcl
Did you know?
WebNov 13, 2014 · You can also set the CC from an application program. In COBOL you would use the RETURN-CODE "special register". MOVE 04 TO RETURN-CODE When executed, … WebJul 7, 2005 · The command SET MAXCC = x is used to override internal return code of IDCAMS. Really there are two Retrun code in IDCAMS that are LASTCC and MAXCC, but …
WebMay 3, 2007 · Can anyone please help to find how to set MAXCC to 24 in jcl . I am getting a RC = for this job . my task is to set the MAXCC to 24 whenever maxcc is between 1 & 19, I have already done this using IDCAMS, but I am asked to find a alternative. Back to top agkshirsagar Active Member Joined: 27 Feb 2007 Posts: 691 Location: Earth WebJan 25, 2024 · IF LASTCC =8 ; SET MAXCC=0. Step 2: Create a new VSAM File DEFINE VSAM-FILE_NAME (COND=(0,LT,STEP1) ... Step3: Next, you must run a JCL command (IDCAMS - Define Cluster) with step-2 results/output (sorting mechanisms) as input. Step4: Finally, to load the flat file into VSAM, use the IDCAMS REPRO command.
WebJul 10, 2024 · The following requirements can be met using below mentioned JCL utilities: 1. Need to check if a data set is empty or not. If it’s empty I want to skip all other steps. 2. Need to skip certain steps in my job if the input is empty. This would be easiest if a utility would generate a non-zero RC if the input is empty. 3. WebDec 8, 2011 · The STATUS command gives the status of jobs, if they are executing or in output queue after completion, So I think we don't have to wait till the job is completed. @kokwind. In your code, Code: SAY LOG.2. PARSE VAR LOG.2 "JOB" JOBID MESSAGE. SAY "JOB "JOBNAME" ("JOBID") "MESSAGE. OUTPUT: Code:
WebUsing the SET command and MAXCC Parameter In this example, if the maximum condition code is 0, the program lists an entry from a catalog and prints a data set. If the maximum condition code is not 0, set the maximum condition code to 8. IF MAXCC=0 THEN DO LISTCAT CATALOG (AMASTCAT/MST27) ENT (MN01.B005) PRINT INFILE (AJK006) END
WebUsing the SET command and MAXCC Parameter z/OS DFSMS Access Method Services Commands SC23-6846-01 In this example, if the maximum condition code is 0, the program lists an entry from a catalog and prints a data set. If the maximum condition code is not 0, … iowa personalsWebDec 15, 2011 · My requirement here is to set the Maxcc=0 if the FTP is successful in either of the three steps. I have already tried the below piece of code:-if ( step020.RC =0 … iowa personals craigslistWebJun 23, 2024 · If one of the data sets isn't there, you can suppress the CC 8 by using an IF LASTCC = 8 after the DELETE or IF MAXCC = 8 as the last card. (Note that 8 can be returned for other reasons other than not in catalog.) iowa personalized plate availabilityWebIf you have CA-DISK: //DMS EXEC DMS SCAN REALVOLS SELECT SGNAME=/,CRIT=(CATSTAT,NE,OK) *not-cataloged and incorrectly cataloged datasets.* opencv calib3d not foundWebMar 25, 2014 · The short answer to your question is No. You can't magically pass the highest Return Code, or Return Code from a previous step, to a program just with JCL. The longer answer is Yes, it will probably be possible to do what you want, however you have asked us how to provide the solution you have come up. opencv calchist examples c++WebNov 18, 2010 · I have requirement as follows,In an input file there will be only one record(FB file) of four characters, I need to check each character and I need to set maxcc based on … opencv built target libprotobufWebSYS1.IMAGELIB data set open with the IMGLIB macro when checkpoint taken. Programmer Response: Ensure that all IMAGELIB DCBs are closed prior to issuing CHKPT. See also IMGLIB. 251: S23F: A data set that was not a checkpoint data set at checkpoint time was found to be open as a secure checkpoint data set at restart time. iowa pet classifieds